How can we help you?
The 0-10V Dimming Photocell Sensor for Street LED Lighting ,JL-241/242/243 series is applicable to control any independent LED home/street lighting automatically in accordance with the ambient natural lighting level.
This Dimming Photocell Sensor is designed with microprocessor circuits with IR-filtered silicone sensor, a heavy duty surge arrester (MOV) is provided to protect the lamp from inrush current as well as impulse by lightening.
Further, a preset 10 seconds time-delay prevents excessive operation due to spotlight or lightning during the night time.
A heavy duty relay supports the work life of over 15,000 cycles, and offers extra long work life when an optional metal Armor is applied together.
This Constant On/Off Dimming Photocell Switch provides Twist Lock terminals and signal contacts meeting the requirements of ANSI C136.41-2013, as well as being listed by UL under the Standard for Plug-In, Locking Type Photocontrols for Use with Area Lighting ANSI/UL773.
Street Light Photocell Sensor 0~10v Dimming Control
-ANSI C136.41-2013 Twist Lock-
-0-10V Dimming-
-Multi-Volts Application-
-IP65 Ready / IP67 Optional-
-40kA Surge Arrester Built-in-
-IR filtered Photodiode Sensor-
-Midnight Dimming-
-LED Decay Compensation Featured-
-Fail-On Mode-
-Metal Armor for Long Life-
Rated Voltage | 110-277VAC, 50/60Hz |
Applicable Voltage Range | 90-305VAC, 50/60Hz |
Rated Loading | 1000W Tungsten, 1800VA Ballast, 5A e-Ballast |
Power Consumption | 1.2W Average |
Typical On/Off Level | 50 Lux |
Typical Time Delay | 10 Sec |
Typical Surge Protection | 640 Joule / 40000 Amp |
Typical IP Protection | IP65 |
Dielectric Strength | 5000 Vrms |
Ambient Temp. | -40 ~ +70 ℃ |
Related Humidity | 99% |
Overall Size | 84(Dia.) x 86mm |
Weight Approx. | 200 gr |
Disconnect power; wire the color coded Dusk to Dawn Photocell Receptacle according to the diagram below.
Push the Photocell Light Switch on and Twist it clockwise to lock it into the Street Light Control Receptacle.
Install the photocontroller with the Photocell facing the NORTH direction as indicated on the top of the photocontroller.
Adjust the receptacle position if necessary.
It is normal for the SWITCH to take several minutes to turn off when first installed.
To test “turn on” during daytime, cover its eye with sliding the metal strip mounted.
Do not cover with finger because light traveling through fingers may be great enough to keep the switch open.
Test will take approximately 2 minutes.