JL-102BR-240VAC-Automatic-Day-Night-Light-Switch
Rate voltage:
Other Options:
200℃
Couple lock-nuts (Null = One lock-nut offered)
Neoprene gasket for outdoor use
Length:
Customizable

Ordering Information

JL-102BR **09 ***G / L M N

*:Model Number

**:Lead Length (in inches)

***:Other Options

G=200℃

L=Couple lock-nuts (Null = One lock-nut offered)

N=Neoprene gasket for outdoor use

Product Summary

The Dusk to Dawn Light Sensor JL-102R is applicable to control the street lighting, passage lighting and doorway lighting automatically in accordance with the ambient lighting level.

This product is complied with the Standard for Non-industrial Photoelectric Dusk to Dawn Sensor Switches for Lighting Control UL773A.


Technical Data

The Photoelectric Dusk to Dawn Light Sensor JL-102 is applicable to control the street lighting, passage lighting and doorway lighting automatically in accordance with the ambient lighting level. This product is complied with the Standard for Non-industrial Photoelectric Dusk to Dawn Light Control Switches for Lighting Control UL773A. This item is now under ETL investigation.


-Product Display-

102BR.jpg

-Product Data-

Model No. JL-102AJL-102B
Rated Voltage120VAC 240VAC
Rated Frequency50/60Hz
Power consumption150W TUNGSTEN 100 VABALLAST
Operate Level10~20Lx On ;30~60Lx Off
Ambient Temperature-40℃ ~ +70℃
Related Humidity 99%RH
Overall Dimensions 35(L) x 19.5(W) x 36(H)mm
Leads Length 7” or Customer request (AWG#18)
Weight Approx.20grs(7” )


产品内页——联系我们.jpg

Installation

Disconnect power, remove junction box cover, place the SWITCH in knockout hole and fasten with locknut. 

Wire according to the diagram in right hand.

Do not install the switch with the Dusk to Dawn Light Sensor facing artificial or reflected light. This will cause the unit to cycle on and off at night.


Initial Testing

It is normal for the SWITCH to take several minutes to turn off when first installed.

To test “turn on” during daytime, cover its eye with sliding the metal strip mounted.

Do not cover with finger because light traveling through fingers may be great enough to keep the switch open.