JL-101-Mini-Dusk-to-Dawn-Photosensor
Rate voltage:
Other Options:
Couple lock-nuts (Null = One lock-nut offered)
Neoprene gasket for outdoor use (Null = Foam plastic gasket for indoor use)
Length:
Customizable

Ordering Information

JL-101A **09 ***/ L N

*:Model Number

**:Lead Length in inches

***:Other Options

L=Couple lock-nuts (Null = One lock-nut offered)

N=Neoprene gasket for outdoor use (Null = Foam plastic gasket for indoor use)

Product Summary

The 12 volt photocell switch circuit JL-101 is applicable to control the street lighting, passage lighting and doorway lighting automatically in accordance with the ambient lighting level.

Technical Data

The photoelectric switch JL-101 is applicable to control the street lighting, passage lighting and

doorway lighting automatically in accordance with the ambient lighting level.

mini longjoin photocell.jpg


Model No.JL-101AJL-101B
Rated Voltage100-120VAC200-240VAC
Rated Frequency50/60Hz
Rated Loading100W TUNGSTEN
Power consumption1.0W max.
Operate Level10~30Lx (On & Off)
Ambient Temperature-20℃ ~ +70℃
Related Humidity 95%RH
Overall Dimensions34.5(L) x 20(W) x 26.4(H)mm
Leads Length7” or Customer request (AWG#20)
Weight Approx.12.5grs(7” )



Installation

Disconnect power, remove junction box cover, place the SWITCH in knockout hole and fasten with locknut. 

Wire according to the diagram in right hand.

Do not install the switch with the Photocell facing artificial or reflected light. This will cause the unit to cycle on and off at night. 


Initial Testing

It is normal for the SWITCH to take several minutes to turn off when first installed.

To test “turn on” during daytime, cover its eye with sliding the metal strip mounted.

Do not cover with finger because light traveling through fingers may be great enough to keep the switch open.

Test will take approximately 2 minutes.