JL-206 NEMA interface Twist-Lock Light Control Switch

JL-206C_09.jpg

JL-206 NEMA interface twist lock CNC optical switch of JL-2 series (reverse proportion)


Product introduction

JL-206C twist lock analog electronic light control switch series products are applicable to independently control street lighting, garden lighting, passage lighting, porch lighting and park lighting according to the ambient natural lighting level.

This series of products has designed a microprocessor circuit with infrared filter optical transistor, and is equipped with a surge arrester (MOV). In addition, the preset 5-20 second time delay control function can avoid redundant operation caused by the spotlight or lightning at night.

The long-life version can maintain constant and reliable characteristics. The relay can have more than 10000 working life cycles. When a double-layer protective shell is installed, it can provide a longer working life for JL-206. HP version can provide a higher load.

This series of products provides three lock terminals, which meet the requirements of ANSI C136.10 and ANSI/UL773 standard for plug-in and rotary lock optical controllers for area lighting.

JL-206C_07_01.jpg

JL-206C_04.jpg

Product Features

·ANSI C136.10 twsit lock
·multi voltage
·Inverse illuminance
·Fully customizable
·Built-in surge protection
·Infrared filter phototransistor
·Midnight light
·Zero crossing protection
·Optional failure mode on/off
·UV-resistant housing
·Support FCC class A


Parameter Table

ItemJL-206C5JL-206C4JL-206C5HPJL-206C4HP
Rated Voltage120-277VAC
Rated Frequcy50/60Hz
Work Temperatue-40℃-70℃
Relative Humidity96%
Rated Loading1000W   Tungsten;1800VA Ballast;8A@120VAC 5A@208-277VAC e-Ballast1800W@120VAC   2000W Tungsten;
    1800VA@120VAC
    Ballast;2000VA@208-277VAC
Power Consumption0.5W Max
0.9 Max
Double CoverOption
IP RatingIP54/IP65/IP66
Fail ModeFail on/Fail off
Cross Zerooption
FCCOptioan-
CertificateUL,CE,ROHS

ItemJL-206E5JL-206E4JL-206F4JL-206F5
Rated Voltage347VAC480VAC
Rated Frequcy50/60Hz
Work Temperatue-40℃-70℃
Relative Humidity96%
Rated Loading1800W Tungsten;1800VA Ballast;5A e-Ballast1800W Tungsten;
    1800VA Ballast
Power Consumption0.5W Max
Double CoverOption
IP RatingIP54/IP65/IP66
Fail ModeFail on/Fail off
Cross Zero-
FCC--
CertificateUL,ROHS

Installation Instructions

*Disconnect the power supply.
*Connect the socket according to the figure below.
*Push the photoelectric controller up and turn it clockwise to lock it in the socket.
*If necessary, adjust the socket position to ensure that the light sensing port points to the north as shown in the triangle on the top of the light controller.
JL-206C_03.jpg




Initial testing

*It is normal for the Photocontrol to take few minutes to turn off when first installed.
*To test “turn on” during daytime, cover its eye with opaque material.
*Do not cover with finger because light traveling through fingers may be great enough to keep the Photocontrol off.
*photocontrol test will take approximately 2 minutes.
* Operation of this Photocontrol is not affected by weather, moisture or temperature changes.


Product Code Table

JL-206C_01.jpg

1: C = 120-277VAC
E = 347VAC
F = 480VAC
2:5=light on
4=light off
3: F12 = MOV,110J/3500A
F15 = MOV,235J/5000A
F23 = MOV,460J/10000A
F25 = MOV,546J/10000A
F40 = MOV,640J/ 40000A
M4K = MOV,4KV Surge

D6K = R/C,6KV Surge

R2W = R/C,20KV Surge

A2W = A/D,20KV Surge

4: F=Conforming to the requirements of FCC electromagnetic interference specification, Class B

N=FCC compliance not verified

5: HP = Hi-Power 20Amp

S = Standard 10Amp

6: P=UV stabilized polypropylene

C=UV stabilized polycarbonate
K=PP inner shell+PC shell

7: F=blue D=green H=black

K=gray optional

8: IP65=elastomer ring+silicone outer seal

IP54=Electronically associated foam washer

IP66=elastomer ring+silicone inner and outer sealing

IP67=silicone ring+silicone inner and outer sealing (including copper pin)
9: Illumination
10: Lamp on delay (seconds)
11: Illumination after turning off the light
12: lamp off delay (seconds)
13: Optional mid-night dimming (hours)
14: Z=optional zero-crossing control technology+long life
N=None