How can we help you?
JL-206 NEMA interface twist lock CNC optical switch of JL-2 series (reverse proportion)
Product introduction
JL-206C twist lock analog electronic light control switch series products are applicable to independently control street lighting, garden lighting, passage lighting, porch lighting and park lighting according to the ambient natural lighting level.
This series of products has designed a microprocessor circuit with infrared filter optical transistor, and is equipped with a surge arrester (MOV). In addition, the preset 5-20 second time delay control function can avoid redundant operation caused by the spotlight or lightning at night.
The long-life version can maintain constant and reliable characteristics. The relay can have more than 10000 working life cycles. When a double-layer protective shell is installed, it can provide a longer working life for JL-206. HP version can provide a higher load.
This series of products provides three lock terminals, which meet the requirements of ANSI C136.10 and ANSI/UL773 standard for plug-in and rotary lock optical controllers for area lighting.
Product Features
·ANSI C136.10 twsit lock
·multi voltage
·Inverse illuminance
·Fully customizable
·Built-in surge protection
·Infrared filter phototransistor
·Midnight light
·Zero crossing protection
·Optional failure mode on/off
·UV-resistant housing
·Support FCC class A
Parameter Table
Item | JL-206C5 | JL-206C4 | JL-206C5HP | JL-206C4HP | |
Rated Voltage | 120-277VAC | ||||
Rated Frequcy | 50/60Hz | ||||
Work Temperatue | -40℃-70℃ | ||||
Relative Humidity | 96% | ||||
Rated Loading | 1000W Tungsten;1800VA Ballast;8A@120VAC 5A@208-277VAC e-Ballast | 1800W@120VAC 2000W Tungsten; 1800VA@120VAC Ballast;2000VA@208-277VAC | |||
Power Consumption | 0.5W Max | 0.9 Max | |||
Double Cover | Option | ||||
IP Rating | IP54/IP65/IP66 | ||||
Fail Mode | Fail on/Fail off | ||||
Cross Zero | option | ||||
FCC | Optioan | - | |||
Certificate | UL,CE,ROHS | ||||
Item | JL-206E5 | JL-206E4 | JL-206F4 | JL-206F5 | |
Rated Voltage | 347VAC | 480VAC | |||
Rated Frequcy | 50/60Hz | ||||
Work Temperatue | -40℃-70℃ | ||||
Relative Humidity | 96% | ||||
Rated Loading | 1800W Tungsten;1800VA Ballast;5A e-Ballast | 1800W Tungsten; 1800VA Ballast | |||
Power Consumption | 0.5W Max | ||||
Double Cover | Option | ||||
IP Rating | IP54/IP65/IP66 | ||||
Fail Mode | Fail on/Fail off | ||||
Cross Zero | - | ||||
FCC | - | - | |||
Certificate | UL,ROHS |
Installation Instructions
*Disconnect the power supply.
*Connect the socket according to the figure below.
*Push the photoelectric controller up and turn it clockwise to lock it in the socket.
*If necessary, adjust the socket position to ensure that the light sensing port points to the north as shown in the triangle on the top of the light controller.
Initial testing
*It is normal for the Photocontrol to take few minutes to turn off when first installed.
*To test “turn on” during daytime, cover its eye with opaque material.
*Do not cover with finger because light traveling through fingers may be great enough to keep the Photocontrol off.
*photocontrol test will take approximately 2 minutes.
* Operation of this Photocontrol is not affected by weather, moisture or temperature changes.
Product Code Table
1: C = 120-277VAC
E = 347VAC
F = 480VAC
2:5=light on
4=light off
3: F12 = MOV,110J/3500A
F15 = MOV,235J/5000A
F23 = MOV,460J/10000A
F25 = MOV,546J/10000A
F40 = MOV,640J/ 40000A
M4K = MOV,4KV Surge
D6K = R/C,6KV Surge
R2W = R/C,20KV Surge
A2W = A/D,20KV Surge
4: F=Conforming to the requirements of FCC electromagnetic interference specification, Class B
N=FCC compliance not verified
5: HP = Hi-Power 20Amp
S = Standard 10Amp
6: P=UV stabilized polypropylene
C=UV stabilized polycarbonate
K=PP inner shell+PC shell
7: F=blue D=green H=black
K=gray optional
8: IP65=elastomer ring+silicone outer seal
IP54=Electronically associated foam washer
IP66=elastomer ring+silicone inner and outer sealing
IP67=silicone ring+silicone inner and outer sealing (including copper pin)
9: Illumination
10: Lamp on delay (seconds)
11: Illumination after turning off the light
12: lamp off delay (seconds)
13: Optional mid-night dimming (hours)
14: Z=optional zero-crossing control technology+long life
N=None