JL-230 Photocell Receptacle
Rate voltage:
Lead Guage:
AWG#14
AWG#16
Lead Grade:
105 degree C, AWM1015 (standard)
150 degree C, AWM3321
Contact Material:
Brass (standard)
Phosphor Bronze
Length:
Customizable

Ordering Information

*JL-230-14 - **06 - ***G - ****P

-:Lead Guage

14=AWG#14

16=AWG#16

**:Lead Length in inches; (‘06’ as min.)

***:Lead Grade

Null=105 degree C, AWM1015 (standard)

G=150 degree C, AWM3321

****:Contact Material

Null=Brass (standard)

P=Phosphor Bronze

Product Summary

All the JL-230 series dusk to dawn automatic photocell light control socket are intended to be pre-mounted onto those lanterns designed to fit an ANSI C136.10-1996 twist-lock photocontrol.

Both dusk to dawn socket JL-230-16 and JL-230-14 have been recognized by UL to applicable US and Canadian safety standards, under their file E188110, Vol.2.


Installation

Disconnect power; wire the receptacle according to the diagram in right hand. An arrow indicating NORTH on the top of the receptacle is used to assist correct direction. Push the photocontroller on and twist it clockwise to lock it into the receptacle. 

Install the photocontroller with the Photocell facing the NORTH direction as indicated on the top of the photocontroller. 

Adjust the receptacle position if necessary.


Initial Testing

For other mounting methods, ask for the drilling plan to ensure the proper securement.